MakerWorld
Other Tools
Ver Modelo
HVAC Rectangular Register Boot / Damper
5
Descargas
8
Likes
1
Makes
I designed a custom register boot and damper to add a heat vent to my basement. I tapped into an existing 12" × 4" rectangular ceiling duct and created a combined starting collar, register boot, and adjustable damper to direct warm air downward. The flange includes screw holes for mounting, and after installing I sealed the joints with HVAC tape before closing the ceiling. The damper lid faces the airflow and can be set at 0° (closed), 10°, 30°, or 45° for adjustable airflow control. This was printed in ABS. The surface looks rough because my nozzle was bent at the time (see photo), but the part works properly and stays hidden in the ceiling so I left it as is.
¿Has impreso este modelo? Inicia sesión y comparte tu make.
Inicia sesión para dejar un comentario
Iniciar sesiónAún no hay comentarios – ¡sé el primero!